ELTRA ELEMENTRAC CS-d Dual-Furnace Carbon/Sulfur Analyzer – Induction + Resistance | ppm–100%
ELTRA ELEMENTRAC CS-d Dual-Furnace Carbon/Sulfur Analyzer – Induction + Resistance | ppm–100%

Dual-furnace analyzer that combines an induction furnace (above 2,000 °C) and a resistance furnace (to 1,550 °C) in one instrument — carbon and sulfur in both inorganic and organic samples, from ppm to 100 %, with up to four gold infrared cells.

  • ✔ ELTRA Dual Furnace (EDF) · induction + resistance · organic & inorganic C/S
  • ✔ ppm to 100 % · up to 4 independent IR cells · gold IR path
  • ✔ Intelligent lance · low-blank port · 36/130 autoloader · TIC · halogen trap
  • ✔ Lead time: configured to order — request current timeline

In stock

· Lead time: configured to order — request current timeline
ELTRA ELEMENTRAC CS-i Induction Carbon/Sulfur Analyzer – Metals & Ceramics | 0.6 ppm–6%+
ELTRA ELEMENTRAC CS-i Induction Carbon/Sulfur Analyzer – Metals & Ceramics | 0.6 ppm–6%+

Induction-furnace analyzer for carbon and sulfur in inorganic samples and metals — combustion above 2,000 °C with up to four infrared cells covering 0.6 ppm to more than 6 % at 1,000 mg, in about 40 seconds.

  • ✔ Induction furnace > 2,000 °C · single or simultaneous C/S · metals & inorganics
  • ✔ 0.6 ppm to 6 %+ · up to 4 IR cells · heated dust trap · Pt catalyst
  • ✔ ~40 s analysis · optional 36/130-position autoloader · TIC module
  • ✔ Lead time: configured to order — request current timeline

In stock

· Lead time: configured to order — request current timeline
ELTRA ELEMENTRAC CS-r Carbon/Sulfur Analyzer – Resistance Furnace + IR | 20 ppm–100%
ELTRA ELEMENTRAC CS-r Carbon/Sulfur Analyzer – Resistance Furnace + IR | 20 ppm–100%

Resistance-furnace analyzer for fast, simultaneous carbon and sulfur in organic matrices — combustion up to 1,550 °C with up to four solid-gold infrared cells over 20 ppm to 100 %, and an optimized low-blank sample port for reliable low-carbon analysis.

  • ✔ Simultaneous C/S · 20 ppm–100 % · high sample weights
  • ✔ Resistance furnace to 1,550 °C (1 °C steps) · up to 4 solid-gold IR cells
  • ✔ Low-blank sample port · dual-furnace option · TIC module (DIN EN 15936)
  • ✔ Lead time: configured to order — request current timeline

In stock

· Lead time: configured to order — request current timeline
ELTRA ELEMENTRAC OH-p 2 Oxygen/Hydrogen Analyzer – Inert Gas Fusion | Steel, Metals & Ceramics
ELTRA ELEMENTRAC OH-p 2 Oxygen/Hydrogen Analyzer – Inert Gas Fusion | Steel, Metals & Ceramics

Inert-gas-fusion analyzer for oxygen and total hydrogen in metals — the sample melts in a graphite crucible in an 8.5 kW impulse furnace above 3,000 °C, with IR detection of oxygen and thermal conductivity for hydrogen.

  • ✔ O / H by fusion · single or combined OH · inorganic samples
  • ✔ 8.5 kW impulse furnace > 3,000 °C · closed gas system · low detection limits
  • ✔ Up to 2000 mg · nitrogen carrier · Schuetze reagent · Autocleaner option
  • ✔ Lead time: configured to order — request current timeline

In stock

· Lead time: configured to order — request current timeline
ELTRA ELEMENTRAC ON-p 2 Oxygen/Nitrogen Analyzer – Inert Gas Fusion | Steel, Metals & Titanium
ELTRA ELEMENTRAC ON-p 2 Oxygen/Nitrogen Analyzer – Inert Gas Fusion | Steel, Metals & Titanium

Inert-gas-fusion analyzer for oxygen and nitrogen in metals — the sample melts in a graphite crucible in an 8.5 kW impulse furnace above 3,000 °C, with IR detection of oxygen and thermal conductivity for nitrogen.

  • ✔ O / N by fusion · single or combined ON · inorganic samples
  • ✔ 8.5 kW impulse furnace > 3,000 °C · closed gas system · low detection limits
  • ✔ Up to 2000 mg · argon carrier possible · Autocleaner option
  • ✔ Lead time: configured to order — request current timeline

In stock

· Lead time: configured to order — request current timeline
ELTRA ELEMENTRAC ONH-p 2 Oxygen/Nitrogen/Hydrogen Analyzer – Inert Gas Fusion | Steel, Metals & Titanium
ELTRA ELEMENTRAC ONH-p 2 Oxygen/Nitrogen/Hydrogen Analyzer – Inert Gas Fusion | Steel, Metals & Titanium

Inert-gas-fusion analyzer for oxygen, nitrogen and hydrogen in metals — the sample melts in a graphite crucible in an 8.5 kW impulse furnace above 3,000 °C, with IR detection of oxygen and thermal conductivity for nitrogen and hydrogen.

  • ✔ O / N / H by fusion · single or ON / OH / NH / ONH · inorganic samples
  • ✔ 8.5 kW impulse furnace > 3,000 °C · closed gas system · low detection limits
  • ✔ Up to 2000 mg · 32-position autoloader · Autocleaner · argon possible
  • ✔ Lead time: configured to order — request current timeline

In stock

· Lead time: configured to order — request current timeline
ELTRA H-500 Hydrogen Analyzer – Hot Extraction + TCD | Steel, Copper & Alloys
ELTRA H-500 Hydrogen Analyzer – Hot Extraction + TCD | Steel, Copper & Alloys

Analyzer for hydrogen in metals by hot extraction — the solid sample drops into a tilting furnace at 900–1,000 °C, and a nitrogen carrier sweeps the diffused hydrogen into a high-capacity thermal conductivity cell in 3–15 minutes.

  • ✔ Residual / diffusible hydrogen · hot extraction · precise at low levels
  • ✔ Tilting furnace 900–1,000 °C · high-capacity thermal conductivity cell
  • ✔ Solid samples up to ø13×60 mm / 10 g · minimal prep
  • ✔ Lead time: configured to order — request current timeline

In stock

· Lead time: configured to order — request current timeline
ELTRA SurfaceC-800 Surface Carbon Analyzer – Combustion + IR | Steel, Aluminum & Ceramics
ELTRA SurfaceC-800 Surface Carbon Analyzer – Combustion + IR | Steel, Aluminum & Ceramics

Dedicated surface-carbon analyzer for solid samples — combustion in a resistance furnace up to 1,000 °C with infrared CO₂ detection, from trace level to 1,000 µg/cm² in 60–90 seconds.

  • ✔ Surface carbon: trace–1,000 µg/cm² · 60–90 s per analysis
  • ✔ Resistance furnace to 1,000 °C · solid-state IR cells (1–2)
  • ✔ Large samples up to 32×145 mm · minimal prep · gold IR path option
  • ✔ Lead time: configured to order — request current timeline