Equipment
Inert-gas-fusion analyzer for oxygen, nitrogen and hydrogen in metals — the sample melts in a graphite crucible in an 8.5 kW impulse furnace above 3,000 °C, with IR detection of oxygen and thermal conductivity for nitrogen and hydrogen.
- ✔ O / N / H by fusion · single or ON / OH / NH / ONH · inorganic samples
- ✔ 8.5 kW impulse furnace > 3,000 °C · closed gas system · low detection limits
- ✔ Up to 2000 mg · 32-position autoloader · Autocleaner · argon possible
- ✔ Lead time: configured to order — request current timeline
In stock
· Lead time: configured to order — request current timeline
Analyzer for hydrogen in metals by hot extraction — the solid sample drops into a tilting furnace at 900–1,000 °C, and a nitrogen carrier sweeps the diffused hydrogen into a high-capacity thermal conductivity cell in 3–15 minutes.
- ✔ Residual / diffusible hydrogen · hot extraction · precise at low levels
- ✔ Tilting furnace 900–1,000 °C · high-capacity thermal conductivity cell
- ✔ Solid samples up to ø13×60 mm / 10 g · minimal prep
- ✔ Lead time: configured to order — request current timeline
In stock
· Lead time: configured to order — request current timeline
Dedicated surface-carbon analyzer for solid samples — combustion in a resistance furnace up to 1,000 °C with infrared CO₂ detection, from trace level to 1,000 µg/cm² in 60–90 seconds.
- ✔ Surface carbon: trace–1,000 µg/cm² · 60–90 s per analysis
- ✔ Resistance furnace to 1,000 °C · solid-state IR cells (1–2)
- ✔ Large samples up to 32×145 mm · minimal prep · gold IR path option
- ✔ Lead time: configured to order — request current timeline
Made to order
· Lead time: configured to order — request current timeline
Manual-lid thermogravimetric analyzer — programmable furnace plus integrated balance measures moisture, ash and volatiles in up to 19 samples per run, 50–1,000 °C. A more economical route to standard-compliant TGA.
- ✔ 19 samples + 1 reference · 500 mg–5 g · moisture/ash/volatiles in one run
- ✔ Ceramic furnace 50–1,000 °C · N₂/O₂/air per stage · manual crucible lids
- ✔ Encapsulated balance 0.1 mg · ASTM D 7582 compliant
- ✔ Lead time: configured to order — request current timeline
Made to order
· Lead time: configured to order — request current timeline
Automated thermogravimetric analyzer that combines a programmable furnace with an integrated balance — measures moisture, ash and volatiles in up to 19 samples per run, 50–1,000 °C.
- ✔ 19 samples + 1 reference · 500 mg–5 g · moisture/ash/volatiles in one run
- ✔ Ceramic furnace 50–1,000 °C · N₂/O₂/air per stage · crucible-lid handling
- ✔ Encapsulated balance 0.1 mg · ASTM D 7582 compliant
- ✔ Lead time: configured to order — request current timeline
Made to order
· Lead time: configured to order — request current timelineNot sure which system fits?
Tell us your application. We'll send our top recommendation.
Browse all categories
Printers, materials, print services and lab equipment — including AO Metal, the LPBF printer we design and build ourselves.
Have a CAD? Have a quote in 24h.
Upload your file or talk to an engineer — no obligation, no spam, NDA on request. First-time customers get free DfAM review.