Equipment
Multi-ramp version of the CW-800 for simultaneous carbon dioxide and water — up to five programmable temperature steps release and resolve TOC/TIC and water fractions without adding acids, measured by infrared cells.
- ✔ CO₂ + water · TOC / TIC without acids · fraction "chromatogram"
- ✔ Up to 5 programmable ramps · resistance furnace to 1,000 °C · 1–2 IR cells
- ✔ Nitrogen & oxygen carrier · gold IR path · no halogen trap
- ✔ Lead time: configured to order — request current timeline
In stock
· Lead time: configured to order — request current timeline
Resistance-furnace analyzer for fast, simultaneous carbon, hydrogen and sulfur in organic matrices — combustion up to 1,550 °C with a heated H₂O infrared cell for hydrogen and solid-gold IR cells over 20 ppm to 100 %.
- ✔ Simultaneous C / H / S · 20 ppm–100 % · high sample weights
- ✔ Resistance furnace to 1,550 °C · heated H₂O IR cell · up to 3 solid-gold IR cells
- ✔ Low-blank sample port · dual-furnace option · TIC module (DIN EN 15936)
- ✔ Lead time: configured to order — request current timeline
In stock
· Lead time: configured to order — request current timeline
Automated Dumas analyzer for nitrogen / protein and carbon — reliable results in under three minutes with interleave processing, over 70× faster than Kjeldahl, on any solid or liquid matrix.
- ✔ Dumas nitrogen / protein + carbon · validated by AOAC, ISO, DIN, AOCS, OIV
- ✔ < 3 min · interleave analysis · TCD (N) + NDIR (C)
- ✔ Integrated PC + touchscreen · FDA 21 CFR Part 11 · CN-r or N-r
- ✔ Lead time: configured to order — request current timeline
In stock
· Lead time: configured to order — request current timeline
Dual-furnace analyzer that combines an induction furnace (above 2,000 °C) and a resistance furnace (to 1,550 °C) in one instrument — carbon and sulfur in both inorganic and organic samples, from ppm to 100 %, with up to four gold infrared cells.
- ✔ ELTRA Dual Furnace (EDF) · induction + resistance · organic & inorganic C/S
- ✔ ppm to 100 % · up to 4 independent IR cells · gold IR path
- ✔ Intelligent lance · low-blank port · 36/130 autoloader · TIC · halogen trap
- ✔ Lead time: configured to order — request current timeline
In stock
· Lead time: configured to order — request current timeline
Induction-furnace analyzer for carbon and sulfur in inorganic samples and metals — combustion above 2,000 °C with up to four infrared cells covering 0.6 ppm to more than 6 % at 1,000 mg, in about 40 seconds.
- ✔ Induction furnace > 2,000 °C · single or simultaneous C/S · metals & inorganics
- ✔ 0.6 ppm to 6 %+ · up to 4 IR cells · heated dust trap · Pt catalyst
- ✔ ~40 s analysis · optional 36/130-position autoloader · TIC module
- ✔ Lead time: configured to order — request current timeline
In stock
· Lead time: configured to order — request current timeline
Resistance-furnace analyzer for fast, simultaneous carbon and sulfur in organic matrices — combustion up to 1,550 °C with up to four solid-gold infrared cells over 20 ppm to 100 %, and an optimized low-blank sample port for reliable low-carbon analysis.
- ✔ Simultaneous C/S · 20 ppm–100 % · high sample weights
- ✔ Resistance furnace to 1,550 °C (1 °C steps) · up to 4 solid-gold IR cells
- ✔ Low-blank sample port · dual-furnace option · TIC module (DIN EN 15936)
- ✔ Lead time: configured to order — request current timeline
In stock
· Lead time: configured to order — request current timeline
Inert-gas-fusion analyzer for oxygen and total hydrogen in metals — the sample melts in a graphite crucible in an 8.5 kW impulse furnace above 3,000 °C, with IR detection of oxygen and thermal conductivity for hydrogen.
- ✔ O / H by fusion · single or combined OH · inorganic samples
- ✔ 8.5 kW impulse furnace > 3,000 °C · closed gas system · low detection limits
- ✔ Up to 2000 mg · nitrogen carrier · Schuetze reagent · Autocleaner option
- ✔ Lead time: configured to order — request current timeline
In stock
· Lead time: configured to order — request current timeline
Inert-gas-fusion analyzer for oxygen and nitrogen in metals — the sample melts in a graphite crucible in an 8.5 kW impulse furnace above 3,000 °C, with IR detection of oxygen and thermal conductivity for nitrogen.
- ✔ O / N by fusion · single or combined ON · inorganic samples
- ✔ 8.5 kW impulse furnace > 3,000 °C · closed gas system · low detection limits
- ✔ Up to 2000 mg · argon carrier possible · Autocleaner option
- ✔ Lead time: configured to order — request current timeline
In stock
· Lead time: configured to order — request current timelineNot sure which system fits?
Tell us your application. We'll send our top recommendation.
Browse all categories
Printers, materials, print services and lab equipment — including AO Metal, the LPBF printer we design and build ourselves.
Have a CAD? Have a quote in 24h.
Upload your file or talk to an engineer — no obligation, no spam, NDA on request. First-time customers get free DfAM review.