Mutual NDA standard before any file review. Talk to an engineer →
C-N-Analyzers, Analysis equipment, Elemental Analyzers

ELTRA ELEMENTRAC CN-r Carbon/Nitrogen Dumas Analyzer – Protein & Nitrogen | Food, Feed & Soil

Automated Dumas analyzer for nitrogen / protein and carbon — reliable results in under three minutes with interleave processing, over 70× faster than Kjeldahl, on any solid or liquid matrix.

  • ✔ Dumas nitrogen / protein + carbon · validated by AOAC, ISO, DIN, AOCS, OIV
  • ✔ < 3 min · interleave analysis · TCD (N) + NDIR (C)
  • ✔ Integrated PC + touchscreen · FDA 21 CFR Part 11 · CN-r or N-r
  • ✔ Lead time: configured to order — request current timeline
Prices follow supplier cost and stock availability and are updated regularly. The price you see is today's price — once you order, it's held for 7 days.
Install + training included Tailored service plan
< 3 min per analysis
70× faster than Kjeldahl
N + C Dumas method
21 CFR 11 compliant software
Built for high-throughput food and feed labs

What your QC lab actually checks

Dumas protein and nitrogen, fast

Automated total nitrogen, protein and carbon determination by the Dumas method — validated by AOAC, AACC, ISO, DIN, ASBC, AOCS and OIV. Interleave processing combusts the current sample while analyzing the previous one, so results come in under three minutes, over 70× faster than Kjeldahl and with no hazardous acids. It handles any matrix, solid or liquid, up to 1 g, at a low cost per sample.

An applications engineer on the line

Dumas calibration, protein-factor setup and blank control from engineers who run materials characterization in-house. Sub-4h reply, NDA standard.

About this product

The ELTRA ELEMENTRAC CN-r is an automated Dumas analyzer for nitrogen / protein and carbon determination. It delivers reliable results in under three minutes at a low cost per sample, using interleave analysis — combustion of the current sample runs while the previous one is being measured. A modern, space-saving alternative to Kjeldahl (results over 70× faster), it has an integrated PC with tiltable touchscreen and FDA 21 CFR Part 11-compliant software, and is available as a carbon-and-nitrogen (CN-r) or nitrogen-only (N-r) analyzer.

Why food, feed and agriculture labs choose the CN-r

Dumas nitrogen, protein and carbon — fast, low-cost, high-throughput.

Dumas nitrogen, protein & carbon

Automated total nitrogen, protein and carbon determination by the Dumas method — internationally recognized and validated by AOAC, AACC, ISO, DIN, ASBC, AOCS and OIV.

Under 3 minutes, interleave

Intelligent interleave processing combusts the current sample while analyzing the previous one, giving results in less than three minutes — over 70× faster than Kjeldahl.

Any matrix, solid or liquid

Precise results across foods, feed, fertilizers, soil and fuels, on solid or liquid samples up to 1 g — with high-priority samples measured immediately, without re-sorting.

21 CFR Part 11, low cost per sample

FDA 21 CFR Part 11-compliant, network-capable ELEMENTS software; gas-saving functions and smart consumable use keep cost per sample low, with all consumables replaceable in under 20 minutes.

How Additive Plus supports it

A configured, installed analyzer with a Dumas method dialed in on your samples.

Step 01
Configure to your samples

We spec the CN-r or N-r configuration, calibration standards and autoloader to your food, feed or soil matrices before it ships.

Step 02
Install & train

Factory-trained engineers install the analyzer, connect oxygen, helium and air, and train your team on the ELEMENTS software.

Step 03
Method & QC support

We help build the SOP — calibration, protein factor setup, blank control and a repeatable Dumas baseline for your standard.

What the CN-r measures

Full technical specifications are in the Specifications tab. Key measurement capability:

Parameter ELEMENTRAC CN-r
Measured Nitrogen / protein and carbon (Dumas method)
Measurement ranges Nitrogen 0.03–300 mg · carbon 0.02–175 mg
Detection Thermal conductivity (N) · NDIR (C)
Sample weight Up to 1.0 g (0.5 g nominal) · solid or liquid
Analysis time < 3 minutes (interleave)
Requirements Oxygen 99.999 % · helium 99.996 % · compressed air · PC/touchscreen integrated
ELTRA ELEMENTRAC CN-r Dumas nitrogen protein carbon analyzer close-up
The ELEMENTRAC CN-r — ergonomic design with an integrated PC and tiltable touchscreen.
ELTRA ELEMENTRAC CN-r analyzer touchscreen with ELEMENTS software
The FDA 21 CFR Part 11-compliant ELEMENTS software on the built-in touchscreen.

Typical sample materials

Protein and nitrogen in food, feed, fertilizers and soil.

Grains & food
Protein content
Dairy & meat
Protein by Dumas
Animal feed
Nutrient composition
Fertilizers
Nitrogen content
Soil
Nitrogen availability
Fuels (coal & coke)
Carbon and nitrogen

Not sure the CN-r is the right analyzer?

Compare with other ELTRA elemental analyzers in our catalog.

Tell us your matrix — food, feed, fertilizer or soil — and whether you need nitrogen/protein only or carbon too, and our applications engineer will confirm the right CN-r or N-r configuration and calibration approach. Sub-4h reply, NDA standard.

Why source the CN-r through Additive Plus

  • Authorized channel for ELTRA / Verder Scientific lab equipment — sales, installation, training and service in one place.
  • Configured to your samples — CN-r or N-r configuration, calibration and autoloader specified before shipping.
  • Method development on your samples — Dumas calibration, protein factors and a repeatable SOP.
  • <24h response from engineers who run materials characterization in-house. NDA standard.
Brand ELTRA
Model ELEMENTRAC CN-r
Measurement ranges Nitrogen: 0.03 mg to 300 mg Carbon: 0.02 mg to 175 mg
Typical weights Up to 1.0 g, 0.5 g nominal
Analysis time < 3 min
Detectors Thermal conductivity detector (N) NDIR (C)
Typical samples Food, feed stuff, fuels (coal and coke), environmental samples and fertilizers
Reagents Magnesium perchlorate, sodium hydroxide, copper, aluminum oxide
Power supply 230 VAC ±10%, 50/60 Hz
Required gas Oxygen (99.999% purity) Helium (99.996% purity) Compressed air (oil and water free)
Configurations CN-r, N-r
Weight 135 kg
Dimensions (W x H x D) 757 x 785 x 620 mm / 29.8 x 30.91 x 24.41 in

Product videos

Common questions

Don't see yours? Email [email protected] — NDA standard, typical reply within 4 hours.

What does the ELTRA ELEMENTRAC CN-r measure?
The ELEMENTRAC CN-r determines total nitrogen (and protein, via a protein factor) and carbon by the Dumas combustion method. It is available in two configurations: a carbon-and-nitrogen analyzer (CN-r) or a nitrogen/protein-only analyzer (N-r). Nitrogen is measured in a thermal conductivity detector and carbon in an NDIR detector, over ranges of 0.03–300 mg N and 0.02–175 mg C.
How does the Dumas method compare to Kjeldahl?
The Dumas method combusts the sample and measures the released nitrogen directly, giving results over 70× faster than Kjeldahl — under three minutes per sample — without hazardous acids or lengthy digestion. It is internationally recognized and validated by AOAC, AACC, ISO, DIN, ASBC, AOCS and OIV, so it is accepted for protein and nitrogen reporting in food, feed and agriculture.
What samples can the CN-r handle?
The CN-r delivers precise Dumas results on any matrix, solid or liquid — foods (grains, dairy, meat), animal feed, fertilizers, soil and fuels such as coal and coke. Typical sample weights are up to 1.0 g, 0.5 g nominal. High-priority samples take precedence and are measured immediately, without re-sorting in the autoloader, which suits busy food and feed labs.
How does interleave analysis speed things up?
Interleave analysis means the CN-r combusts the current sample while it is still measuring the previous one, rather than running them strictly one after another. This overlap is what allows results in under three minutes and high daily throughput, and it is one of the reasons the cost per sample is low. Intelligent gas-saving functions and smart consumable use reduce running costs further.
Is the CN-r software compliant for regulated labs?
Yes. The Windows-based ELEMENTS software is FDA 21 CFR Part 11 compliant and includes an audit trail, user-group management, calibration and diagnostics. Thanks to its network integrity and web-browser architecture, you can access the analyzer from any computer on the company network and have all data available at any time — useful for regulated food, feed and pharmaceutical environments.
What does the CN-r need to run?
It needs oxygen (99.999 % purity), helium (99.996 % purity) and oil- and water-free compressed air, and runs on 230 VAC ±10 %, 50/60 Hz. Reagents are magnesium perchlorate, sodium hydroxide, copper and aluminum oxide. An integrated PC with tiltable touchscreen is built in, and all consumables can be replaced in under 20 minutes. The analyzer measures about 757 × 785 × 620 mm and weighs 135 kg.
What is the lead time, and can Additive Plus set it up?
The ELEMENTRAC CN-r is configured to order; request a quote for the current lead time. Additive Plus is an authorized ELTRA / Verder Scientific channel and handles installation, gas connection, calibration and operator training, then helps build your Dumas nitrogen/protein SOP and protein factors. You can also send a sample for a paid measurement first. Sub-4h reply, NDA standard.

Place your order, or talk to an engineer first

Order ELTRA ELEMENTRAC CN-r Carbon/Nitrogen Dumas Analyzer – Protein & Nitrogen | Food, Feed & Soil direct, or talk to materials engineer

Add to cart