In stock
- Installation & training on-site setup, gas connection and operator onboarding
- Method + calibration a C/S SOP set up on your samples
ELTRA ELEMENTRAC CS-r Carbon/Sulfur Analyzer – Resistance Furnace + IR | 20 ppm–100%
Resistance-furnace analyzer for fast, simultaneous carbon and sulfur in organic matrices — combustion up to 1,550 °C with up to four solid-gold infrared cells over 20 ppm to 100 %, and an optimized low-blank sample port for reliable low-carbon analysis.
- ✔ Simultaneous C/S · 20 ppm–100 % · high sample weights
- ✔ Resistance furnace to 1,550 °C (1 °C steps) · up to 4 solid-gold IR cells
- ✔ Low-blank sample port · dual-furnace option · TIC module (DIN EN 15936)
- ✔ Lead time: configured to order — request current timeline
What your QC lab actually checks
Reliable C/S down to low ppm
Combustion in a resistance furnace to 1,550 °C, with two drying columns and up to four solid-gold infrared cells, determines carbon and sulfur simultaneously from 20 ppm to 100 %. An optimized low-blank sample port with reduced diameter and oxygen purge drastically lowers the atmospheric CO₂ blank, so even low-carbon organic samples are measured reliably. An optional second furnace adds fast fractionated analysis.
An applications engineer on the line
IR-cell configuration, low-blank port and dual-furnace setup, calibration and blank control from engineers who run materials characterization in-house. Sub-4h reply, NDA standard.
The ELTRA ELEMENTRAC CS-r is a resistance-furnace analyzer for fast, simultaneous carbon and sulfur in predominantly organic matrices. The sample is burned in oxygen at up to 1,550 °C (adjustable in 1 °C steps); after the water vapor is removed by two drying columns, the CO₂ and SO₂ are measured in up to four solid-gold infrared cells over a wide range from 20 ppm to 100 %. An optimized low-blank sample port makes reliable low-carbon analysis possible, and an optional second furnace enables fast fractionated analysis.
Why materials and environmental labs choose the CS-r
Reliable carbon and sulfur in organics — down to low ppm, up to 100 %.
Simultaneous C/S, 20 ppm–100 %
Fast, simultaneous carbon and sulfur over a wide range from 20 ppm to 100 % in a resistance furnace up to 1,550 °C, with high sample weights for heterogeneous matrices.
Optimized low-blank sample port
A reduced-diameter sample port with an oxygen purge at the inlet drastically lowers the atmospheric CO₂ blank, enabling reliable carbon analysis in the low measuring range.
Solid-gold IR path, up to 4 cells
A solid-gold IR path gives extended cell lifetime, and up to four infrared cells with different sensitivities cover both low and high concentrations reliably.
Dual-furnace option + TIC
An optional second furnace (ELTRA Dual Furnace Concept) enables fast fractionated analysis at different temperatures; the TIC module adds direct TIC by acidification to DIN EN 15936.
How Additive Plus supports it
A configured, installed analyzer with a carbon/sulfur method dialed in on your samples.
Configure to your samples
We spec the IR cells, sample-port setup, dual-furnace and TIC options to your matrix and concentration range before it ships.
Install & train
Factory-trained engineers install the analyzer, connect oxygen and the PC/balance, and train your team on the ELEMENTS software.
Method & QC support
We help build the SOP — calibration with standards, blank control, TOC/TIC method and a repeatable carbon/sulfur baseline.
What the CS-r measures
Full technical specifications are in the Specifications tab. Key measurement capability:
| Parameter | ELEMENTRAC CS-r |
|---|---|
| Measured elements | Carbon, sulfur (organic samples) |
| Measuring range | 20 ppm to 100 % |
| Principle | Resistance furnace to 1,550 °C (1 °C steps) + solid-state infrared absorption |
| Detection | 1–4 infrared cells · solid-gold IR path |
| Analysis time | ~60–180 seconds |
| Requirements | Oxygen 99.5 % · PC, monitor, 0.0001 g balance |


Typical sample materials
Carbon and sulfur in fuels, biomass, soils and organic matrices.
Not sure the CS-r is the right analyzer?
Compare with other ELEMENTRAC combustion analyzers.
Dual furnaceELEMENTRAC CS-dView analyzer →
Metals / inductionELEMENTRAC CS-iView analyzer →
Why source the CS-r through Additive Plus
- Authorized channel for ELTRA / Verder Scientific lab equipment — sales, installation, training and service in one place.
- Configured to your samples — IR cells, sample-port, dual-furnace and TIC options specified before shipping.
- Method development on your samples — calibration, blank control and a repeatable carbon/sulfur / TOC SOP.
- <24h response from engineers who run materials characterization in-house. NDA standard.
| Brand | ELTRA |
| Model | ELEMENTRAC CS‑r |
| Measured elements | carbon, sulfur |
| Samples | organic |
| Furnace alignment | horizontal (resistance furnace) |
| Sample carrier | ceramic boats |
| Field of application | agriculture, biology, chemistry / plastics, coal / power plant, construction materials, environment / recycling, medicine / pharmaceuticals |
| Furnace | resistance furnace (ceramic tube), adjustable up to 1550 °C (steps of 1 °C) |
| Detection method | solid state infrared absorption |
| Number of IR cells | 1 - 4 |
| Material of IR path | gold |
| Typical analysis time | 60 - 180 s |
| Chemicals required | magnesium perchlorate, sodium hydroxide |
| Gas required | oxygen 99.5 % pure (2 - 4 bar / 30 - 60 psi) |
| Power requirements | 230 V, 50/60 H, max. heating up current 20 A |
| Dimensions (W x H x D) | 580 x 520 x 750 mm / 22.83 x 20.47 x 29.53 in |
| Weight | ~ 77 kg |
| Required equipment | PC, monitor, balance (resolution 0.0001g) |
| Optional accessories | TIC module |
Product videos
From materials and environmental labs running the ELTRA ELEMENTRAC CS-r
Unedited feedback from combustion-analysis teams.
Carbon and sulfur on coal and coke, and the low-blank port finally gives us reliable low-carbon numbers on soils.
Sulfur in oil and fuels across a wide range on the same instrument. The solid-gold IR path has held up well.
TIC by acidification on building materials to the DIN standard. Reporting is clean and repeatable.
Common questions
Don't see yours? Email [email protected] — NDA standard, typical reply within 4 hours.
What does the ELTRA ELEMENTRAC CS-r measure?
How does the measurement work?
How does the low-blank sample port help?
Can the CS-r run TOC and TIC?
What is the dual-furnace option?
What does the CS-r need to run?
What is the lead time, and can Additive Plus set it up?
Place your order, or talk to an engineer first
Order ELTRA ELEMENTRAC CS-r Carbon/Sulfur Analyzer – Resistance Furnace + IR | 20 ppm–100% direct, or talk to materials engineer