Made to order
- Installation & training gas & exhaust connection and operator onboarding
- Method + validation an SOP validated against your standard
ELTRA TGA Thermostep Thermogravimetric Analyzer – Moisture, Ash & Volatiles | 19 Samples, 1000 °C
Automated thermogravimetric analyzer that combines a programmable furnace with an integrated balance — measures moisture, ash and volatiles in up to 19 samples per run, 50–1,000 °C.
- ✔ 19 samples + 1 reference · 500 mg–5 g · moisture/ash/volatiles in one run
- ✔ Ceramic furnace 50–1,000 °C · N₂/O₂/air per stage · crucible-lid handling
- ✔ Encapsulated balance 0.1 mg · ASTM D 7582 compliant
- ✔ Lead time: configured to order — request current timeline
What your QC lab actually checks
Moisture, ash & volatiles in one run
A programmable ceramic furnace (50–1,000 °C) tied to an encapsulated balance measures moisture, ash and volatiles on up to 19 samples plus a reference in a single automated cycle. Automatic crucible-lid handling and selectable N₂/O₂/air make it ASTM D 7582-compliant for coal and ideal for LOI and ash across many materials.
An applications engineer on the line
SOP setup, standard validation and throughput-workflow development from engineers who run materials characterization in-house. Sub-4h reply, NDA standard.
The ELTRA TGA Thermostep is a thermogravimetric analyzer that combines a programmable furnace with an integrated balance, so heating and weighing happen in one instrument. It measures moisture, ash and volatiles in a single automated run, on up to 19 samples plus a reference, at temperatures freely defined from 50 to 1,000 °C — an efficient, high-throughput alternative to laboratory ovens and muffle furnaces.
Why QC labs choose the TGA Thermostep
Automated moisture, ash and volatiles — many samples, one run, one SOP.
19 samples in one run
A carousel processes up to 19 samples plus a reference (500 mg–5 g each). Weigh in place or load a pre-weighed carousel — high throughput without manual oven-and-balance cycling.
Moisture, ash & volatiles together
A programmable ceramic furnace (50–1,000 °C in 1 °C steps) with automatic crucible-lid handling determines all three parameters in one cycle — ASTM D 7582 compliant for coal.
Selectable atmospheres
Choose nitrogen, oxygen or ambient air at each stage of the analysis, so you can gently oxidize or protect the sample exactly when the method requires it.
Precise, stable weighing
An encapsulated weighing cell (0.1 mg resolution, 0.02% RSD) isolated from the ambient atmosphere, with dual non-encapsulated thermocouples for fast, precise temperature control.
How Additive Plus supports it
A configured, installed analyzer with your TGA methods ready to run.
Configure to your samples
We set up the SOPs — temperatures, atmospheres, heating stages and lid handling — for your material and standard before it ships.
Install & train
Factory-trained engineers install, connect the gases and exhaust, and train your team on weighing, SOPs and results.
Method & QC support
We help validate the method against your standard — ASTM D 7582, LOI or dry-mass/ash — and build a repeatable throughput workflow.
What the TGA Thermostep measures
Full technical specifications are in the Specifications tab. Key measurement capability:
| Parameter | TGA Thermostep |
|---|---|
| Measures | Moisture, ash, volatiles (loss on ignition) |
| Samples per run | 19 crucibles + 1 reference · 500 mg – 5 g each |
| Furnace | Resistance-heated ceramic, 50–1,000 °C in 1 °C steps |
| Atmospheres | Nitrogen, oxygen or air, selectable per stage |
| Balance | Encapsulated cell, 0.1 mg resolution, 0.02% RSD |
| Standards | ASTM D 7582 (coal volatiles) · LOI methods |

Typical applications
Moisture, ash and volatiles across many industries.
Not sure the TGA Thermostep is the right fit?
Higher capacity, or a different elemental measurement.
Surface carbonELTRA SurfaceC-800Compare analyzer →
Fit out the labQATM Lab FurnitureView system →
Why source the TGA Thermostep through Additive Plus
- Authorized channel for ELTRA / Verder Scientific lab equipment — sales, installation, training and service in one place.
- Full materials-QC line — thermogravimetry, carbon analysis, sample prep and optical inspection from one partner.
- Method development on your samples — SOPs, standard validation and a repeatable throughput workflow.
- <24h response from engineers who run materials characterization in-house. NDA standard.
| Brand | ELTRA |
| Model | TGA Thermostep |
| Measured elements | ash content, moisture, volatiles |
| Samples | inorganic, organic, synthetic |
| Field of application | agriculture, biology, chemistry / plastics, coal / power plant, construction materials, environment / recycling, food, geology / mining, glass / ceramics, medicine / pharmaceuticals |
| Furnace | resistance heated ceramic furnace, programmable in 1 °C steps from 50 °C up to 1000 °C |
| Detection method | balance |
| Max. number of samples | 19 crucibles + 1 reference crucible |
| Balance resolution | 0.0001 g |
| Gas required | depends on application: oxygen 99.9 % pure (2 - 4 bar) and,or nitrogen 99.9 % pure (2 - 4 bar) and air 99.5 % (5 - 6 bar) |
| Power requirements | 230 V, 50/60 Hz, max. 32 A |
| Dimensions (W x H x D) | 550 x 520 x 620 mm / 21.65 x 20.47 x 24.41 in |
| Weight | ~ 65 kg |
| Required equipment | PC, monitor, external exhaust (exhaust diameter: 100 mm / blower with 4m-3/min) |
Common questions
Don't see yours? Email [email protected] — NDA standard, typical reply within 4 hours.
What does the ELTRA TGA Thermostep measure?
How many samples can it run at once?
What temperature range and atmospheres does it support?
What is the crucible-lid handling for?
Which materials and standards is it used for?
What does it need to run?
What is the lead time, and can Additive Plus set it up?
Place your order, or talk to an engineer first
Order ELTRA TGA Thermostep Thermogravimetric Analyzer – Moisture, Ash & Volatiles | 19 Samples, 1000 °C direct, or talk to materials engineer