Furnances, Atmosphere Controlled Ovens
CONTROLLED ATMOSPHERE OVEN - HTMA
The HTMA series is a range of modified atmosphere high temperature ovens for use with inert atmospheres up to 700°C.
NDA standard Ships in 1–2 business days Spec-match guarantee on every lot
60+AM teams supplied
Lot-to-lotstable PSD & chemistry
COA + parametersin every order
Fast dispatchL.A. stock · M–F
Built for production teams
What your process engineer actually checks
Locked, traceable lot chemistry
Every lot ships with a COA documenting PSD, sphericity, flow rate, apparent density, and full
chemistry — and a lot number you can trace. Aerospace and medical teams reorder 4+ times without
re-qualifying.
Qualified parameters, not just powder
Validated parameter sets for EOS M 290, Renishaw 500Q, SLM 280, and our own AO Metal LPBF ship
with the order. Load the profile and hit density on the first build — no parameter-development burn.
A materials engineer on the line
Questions on ferrite content, flowability, recyclate ratios, or HIP response? A materials engineer
answers directly — not a contact-form bot. Most replies in under 4 hours, NDA standard.
About this product
STANDARD FEATURES • 400°C, 500°C, 600°C or 700°C operating temperatures • 28, 95, 220, 500 & 1000 litre capacities • Carbolite Gero 301 controller, with single ramp to set-point & process timer • Rear mounted fan & side air guides give horizontal ‘airflow’ • Fully seam welded to contain modified atmosphere • Manual gas control via needle valves & flowmeters (nickel brass) • Corrosion resistant stainless steel interior with perforated non-tip shelves & runners • Stainless steel pipe-work, nickel brass flow-meter & solenoid valves • Single side hinged door, with metal heat seal & rubber gas tight seal, closed using non slam handle • Hard wearing, zinc coated & stoved epoxy polyester coated exterior • Gas inlet connection: bulkhead compression fitting to suit 10 mm outside diameter tube (maximum inlet pressure = 2 bar) • Door switch
OPTIONS (SPECIFY THESE AT TIME OF ORDER) • A range of sophisticated digital controllers, multi-segment programmers and data loggers is available. These can be fitted with RS232, RS485 or Ethernet communications – more information • Automatic gas control (requires a EPC3016P1, CC-T1, EPC3008P10 or Nanodac series programmable controller) • Stainless steel flow-meter & solenoid valves, instead of nickel brass • Fixed or castor mounted floor stands • Flow failure alarm • Oxygen sensor fitted to gas outlet to monitor oxygen level, displayed as ppm (parts per million) or percentage. Only available for use with nanodac instruments
STANDARD FEATURES • 400°C, 500°C, 600°C or 700°C operating temperatures • 28, 95, 220, 500 & 1000 litre capacities • Carbolite Gero 301 controller, with single ramp to set-point & process timer • Rear mounted fan & side air guides give horizontal ‘airflow’ • Fully seam welded to contain modified atmosphere • Manual gas control via needle valves & flowmeters (nickel brass) • Corrosion resistant stainless steel interior with perforated non-tip shelves & runners • Stainless steel pipe-work, nickel brass flow-meter & solenoid valves • Single side hinged door, with metal heat seal & rubber gas tight seal, closed using non slam handle • Hard wearing, zinc coated & stoved epoxy polyester coated exterior • Gas inlet connection: bulkhead compression fitting to suit 10 mm outside diameter tube (maximum inlet pressure = 2 bar) • Door switch
OPTIONS (SPECIFY THESE AT TIME OF ORDER) • A range of sophisticated digital controllers, multi-segment programmers and data loggers is available. These can be fitted with RS232, RS485 or Ethernet communications – more information • Automatic gas control (requires a EPC3016P1, CC-T1, EPC3008P10 or Nanodac series programmable controller) • Stainless steel flow-meter & solenoid valves, instead of nickel brass • Fixed or castor mounted floor stands • Flow failure alarm • Oxygen sensor fitted to gas outlet to monitor oxygen level, displayed as ppm (parts per million) or percentage. Only available for use with nanodac instruments
HTMA 6/28 with 3508P1 programmer and automatic gas control optionsHTMA 6/220 with nanodac programmer, automatic gas control and oxygen monitoring optionsHTMA 6/28 with 3508P1 programmer and automatic gas control optionsHTMA 6/220 with nanodac programmer, automatic gas control and oxygen monitoring options
HTMA 4/28
Max temp (°C)
400
Volume (litres)
28
HTMA 4/95
Max temp (°C)
400
Volume (litres)
95
HTMA 4/220
Max temp (°C)
400
Volume (litres)
220
HTMA 4/500
Max temp (°C)
400
Volume (litres)
500
HTMA 4/1000
Max temp (°C)
400
Volume (litres)
1000
HTMA 5/28
Max temp (°C)
500
Volume (litres)
28
HTMA 5/95
Max temp (°C)
500
Volume (litres)
95
HTMA 5/220
Max temp (°C)
500
Volume (litres)
220
HTMA 5/500
Max temp (°C)
500
Volume (litres)
500
HTMA 5/1000
Max temp (°C)
500
Volume (litres)
1000
HTMA 6/28
Max temp (°C)
600
Volume (litres)
28
HTMA 6/95
Max temp (°C)
600
Volume (litres)
95
HTMA 6/220
Max temp (°C)
600
Volume (litres)
220
HTMA 6/500
Max temp (°C)
600
Volume (litres)
500
HTMA 6/1000
Max temp (°C)
600
Volume (litres)
1000
HTMA 7/28
Max temp (°C)
700
Volume (litres)
28
HTMA 7/95
Max temp (°C)
700
Volume (litres)
95
HTMA 7/220
Max temp (°C)
700
Volume (litres)
220
HTMA 4/28
Max temp (°C)
400
Volume (litres)
28
HTMA 4/95
Max temp (°C)
400
Volume (litres)
95
HTMA 4/220
Max temp (°C)
400
Volume (litres)
220
HTMA 4/500
Max temp (°C)
400
Volume (litres)
500
HTMA 4/1000
Max temp (°C)
400
Volume (litres)
1000
HTMA 5/28
Max temp (°C)
500
Volume (litres)
28
HTMA 5/95
Max temp (°C)
500
Volume (litres)
95
HTMA 5/220
Max temp (°C)
500
Volume (litres)
220
HTMA 5/500
Max temp (°C)
500
Volume (litres)
500
HTMA 5/1000
Max temp (°C)
500
Volume (litres)
1000
HTMA 6/28
Max temp (°C)
600
Volume (litres)
28
HTMA 6/95
Max temp (°C)
600
Volume (litres)
95
HTMA 6/220
Max temp (°C)
600
Volume (litres)
220
HTMA 6/500
Max temp (°C)
600
Volume (litres)
500
HTMA 6/1000
Max temp (°C)
600
Volume (litres)
1000
HTMA 7/28
Max temp (°C)
700
Volume (litres)
28
HTMA 7/95
Max temp (°C)
700
Volume (litres)
95
HTMA 7/220
Max temp (°C)
700
Volume (litres)
220
Brand
Carbolite Gero
Model
HTMA 6/28
Max temp
600°C
Volume (litres)
28
Heat-up time (mins)
60
Recovery time (mins)
10
Dimensions: Internal H x W x D
305 x 305 x 305 mm / 12.01 x 12.01 x 12.01 in
Dimensions: External H x W x D
990 x 810 x 885 mm / 38.98 x 31.89 x 34.84 in
Shelves fitted / accepted
2 / 2
Shelf loading each / total (kg)
10 / 20
Max power (W)
2000
Weight (kg)
73
Full documentation — TDS, SDS, batch COA, and parameter sets for the major LPBF platforms.
Everything you need for qualification under AS9100 / ISO 13485 workflows.
From process engineers running CONTROLLED ATMOSPHERE OVEN - HTMA
Unedited feedback from customers who reorder CONTROLLED ATMOSPHERE OVEN - HTMA.
★★★★★4.9 / 5 · 24 reviews
★★★★★
Same lot 4 times in a row. We stopped re-running parameter sweeps after the second order — density
was identical to the first build.
MK
Marcus K.
Process Engineer · Aerospace OEM
★★★★★
Asked about ferrite content on a Friday. A materials engineer answered Monday morning with actual
data, not a sales pitch. That's why we keep ordering.
PS
Priya S.
R&D Lead · Medical Devices
★★★★★
COA matches the bottle. PSD and flow are exactly what was on the sheet — we run it on a Renishaw 500Q
and it hits density on the first try.
DR
Diego R.
Production Lead · Energy
Place your order, or talk to an engineer first
Order 316L direct, or send your application and we'll recommend the right alloy and PSD for your
printer.
Tell us about your part. A real applications engineer reviews every quote — no
contact-form roulette. NDA standard, free DfAM review for first-time customers.
Engineering consult · 30 min
Talk to an applications engineer
30 minutes with the team that designs AO Metal and runs our print services. We'll
review your spec, recommend a process, and send a tailored proposal — installation, training, service
included.
Equipment demo · L.A. or remote
Book a demo with the team that built it
See the equipment running on a real part — in our L.A. shop or remotely. The engineer
on the call is the one who'll support the machine after it ships.
New customer offer
Free DfAM review + free U.S. shipping on your first order.
Real engineering review by an applications engineer — not an automated check.
Plus free domestic shipping, no minimum. Claim it once per company.
Engineer-reviewed quote within 24 hours
Free DfAM & material recommendation ($150 value)
Free U.S. shipping (no minimum on first order)
NDA signed before file review
One per company · first-order only · expires in 30 days
Claim your offer
Takes 30 seconds. We'll reply within 24h with your claim code and a quote-ready
link.
Request a Quote
Engineer-reviewed · Confidential · Fast response
Request a Quote
Engineer-reviewed · Confidential · Fast response
Request a Quote
Engineer-reviewed · Confidential · Fast response
Request a Quote
Engineer-reviewed · Confidential · Fast response
Get My Quote
Engineer-reviewed · Confidential · Fast response
Scan My Object
Please describe your part and scanning needs. Include details like size, material, and how you plan to use the 3D model. Let us know if you require additional services like digital sculpting. Upload images of your part(s) if you have them.
Engineer-reviewed · Confidential · Fast response
Request a 3D Printing Quote
Upload your CAD file or describe your project — our engineers will follow up shortly.