O-N-H Analyzers, Analysis equipment, Elemental Analyzers

ELEMENTRAC ON‑p 2

ELEMENTRAC ON-p 2 is a elemental analyzer for measurement of oxygen and nitrogen concentrations
Lot # and price held 7 days after order.
NDA standard Ships in 1–2 business days Spec-match guarantee on every lot
60+AM teams supplied
Lot-to-lotstable PSD & chemistry
COA + parametersin every order
Fast dispatchL.A. stock · M–F
Built for production teams

What your process engineer actually checks

Locked, traceable lot chemistry

Every lot ships with a COA documenting PSD, sphericity, flow rate, apparent density, and full chemistry — and a lot number you can trace. Aerospace and medical teams reorder 4+ times without re-qualifying.

Qualified parameters, not just powder

Validated parameter sets for EOS M 290, Renishaw 500Q, SLM 280, and our own AO Metal LPBF ship with the order. Load the profile and hit density on the first build — no parameter-development burn.

A materials engineer on the line

Questions on ferrite content, flowability, recyclate ratios, or HIP response? A materials engineer answers directly — not a contact-form bot. Most replies in under 4 hours, NDA standard.

About this product

OXYGEN / NITROGEN ANALYZER ELEMENTRAC ON-P 2

• Low gas consumption and high sensitivity due to closed gas system
• Easy application of pins, powders and granules
• Inexpensive argon as carrier gas possible
• Short analysis time
• Powerful impulse furnace with 8.5 kW
• Optional Autocleaner
• Reliable ON elemental analysis of inorganic samples like steel, non-ferrous metals, ceramics, slags, ores, etc.

• Low gas consumption and high sensitivity due to closed gas system
• Easy application of pins, powders and granules
• Inexpensive argon as carrier gas possible
• Short analysis time
• Powerful impulse furnace with 8.5 kW
• Optional Autocleaner
• Reliable ON elemental analysis of inorganic samples like steel, non-ferrous metals, ceramics, slags, ores, etc.

CONFIGURATIONS

The ELEMENTRAC ON-p 2 elemental analyzer is available as a single-element analyzer for oxygen or nitrogen only, or in a multi-element configuration for measuring ON. Whereas oxygen is determined as CO2 in up to two infrared cells, nitrogen is detected in its elemental form in a thermal conductivity cell.

CUVETTE WITH VARIABLE LENGTH

THERMAL CONDUCTIVITY CELL WITH HIGH SENSITIVITY

CUVETTE WITH VARIABLE LENGTH

THERMAL CONDUCTIVITY CELL WITH HIGH SENSITIVITY




INTEGRATED STANDARD SOLUTIONS

The chemicals and filters required for operation of the elemental analyzer are arranged conveniently on the front panel and can be concealed behind a removable door during routine operation. This arrangement significantly reduces the time required for maintenance and increases user-friendliness. In addition, innovative details considerably improve the reproducibility of measurements.

Innovative sample port & pulsed chamber flushing

The new sample port of the ON-p 2 elemental analyzer ensures comfortable operation and reproducible measured values. Differently shaped materials like solid pieces, granules or powder in capsules can be applied up to a weight of 2000 mg, and are quickly freed from the surrounding atmosphere with the help of pulsed carrier gas flushing in the sample port. Then they drop vertically into the preheated graphite crucible for analysis.

•  Robust against dust development
•  No closing of capsules required
•  Direct application of up to 2000 mg granulate
•  Low in maintenance and wear

Innovative sample port & pulsed chamber flushing

The new sample port of the ON-p 2 elemental analyzer ensures comfortable operation and reproducible measured values. Differently shaped materials like solid pieces, granules or powder in capsules can be applied up to a weight of 2000 mg, and are quickly freed from the surrounding atmosphere with the help of pulsed carrier gas flushing in the sample port. Then they drop vertically into the preheated graphite crucible for analysis.

•  Robust against dust development
•  No closing of capsules required
•  Direct application of up to 2000 mg granulate
•  Low in maintenance and wear

Powerful catalyst

During elemental analysis in the graphite crucible, carbon monoxide (CO) is produced which is converted to carbon dioxide (CO2) in the catalyst and subsequently detected in the IR cells. The easy-to-maintain catalyst with copper oxide filling ensures complete oxidation and thus, reliable oxygen analysis even of difficult materials such as oxides.

Closed gas management

The ELEMENTRAC ONH elemental analyzer series uses a closed gas system in overpressure. This ensures that always 100% of the released sample gas is fed to the detectors which guarantees low detection limits and good reproducibility.

Powerful catalyst

During elemental analysis in the graphite crucible, carbon monoxide (CO) is produced which is converted to carbon dioxide (CO2) in the catalyst and subsequently detected in the IR cells. The easy-to-maintain catalyst with copper oxide filling ensures complete oxidation and thus, reliable oxygen analysis even of difficult materials such as oxides.

Closed gas management

The ELEMENTRAC ONH elemental analyzer series uses a closed gas system in overpressure. This ensures that always 100% of the released sample gas is fed to the detectors which guarantees low detection limits and good reproducibility.

Options

In addition to the integrated solutions of the ELEMENTRAC ON-p 2, further options are available to increase efficiency and extend the application range of your elemental analysis.

AUTOCLEANER

By melting the sample in a graphite crucible at temperatures of up to 3000 °C deposits are generated at the upper electrode and in the furnace chamber which may affect the reproducibility of ONH measurements in a negative way.

The new optional Autocleaner reliably removes these deposits, enabling precise elemental analysis even for high throughputs. Additionally, an efficient gas calibration and cleaning furnace for thorough carrier gas pre-cleaning are available for the elemental analyzer.

AUTOCLEANER

By melting the sample in a graphite crucible at temperatures of up to 3000 °C deposits are generated at the upper electrode and in the furnace chamber which may affect the reproducibility of ONH measurements in a negative way.

The new optional Autocleaner reliably removes these deposits, enabling precise elemental analysis even for high throughputs. Additionally, an efficient gas calibration and cleaning furnace for thorough carrier gas pre-cleaning are available for the elemental analyzer.

Software

The comprehensive Windows-based ELEMENTS software is an essential part of all ELEMENTRAC generation elemental analyzers.

A central window (analysis and results) is the starting point from which all functionalities required for the daily routine are easily accessible. From here it is possible to group and export analyzed samples, or register and analyze new ones. The user may call up various subordinate functionalities like application settings, calibration, diagnosis, or status.

llproductselementssoftwarehl (1)

The comprehensive Windows-based ELEMENTS software is an essential part of all ELEMENTRAC generation elemental analyzers.

A central window (analysis and results) is the starting point from which all functionalities required for the daily routine are easily accessible. From here it is possible to group and export analyzed samples, or register and analyze new ones. The user may call up various subordinate functionalities like application settings, calibration, diagnosis, or status.

llproductselementssoftwarehl (1)

TYPICAL SAMPLE MATERIALS

Alloys, aluminum, ashes, carbides, cast iron, ceramics, copper, ferroalloys, iron, metals, ores, refractory metals, silicon, steel

FUNCTIONAL PRINCIPLE

The measuring principle of the ELEMENTRAC ON-p 2 elemental analyzer allows for a wide measuring range. To analyze the sample, it is weighed and placed on the sample port. Flushing with carrier gas prevents atmospheric gas (oxygen and nitrogen) from getting into the furnace.

The graphite crucible is outgassed in the impulse furnace of the analyzer to reduce possible contaminations (e.g. residual hydrogen). After a stabilization phase the sample is dropped into the crucible and melts. Carbon monoxide is produced by the reaction of carbon in the graphite crucible and oxygen of the material. Nitrogen and hydrogen are released in its elemental form. The carrier gas (helium) and sample gasses pass through a filter before entering a copper oxide catalyst which converts the CO to CO2.

The CO2 is then measured by infrared cells to determine the oxygen content. CO2 and water are removed chemically and the nitrogen content is measured in the thermal conductivity cell. As an option the less expensive Argon can be used in the elemental analyzer to determinate the oxygen and nitrogen content.

Brand ELTRA
Model ELEMENTRAC ON-p 2
Measured elements nitrogen, oxygen
Samples inorganic
Furnace alignment vertical
Sample carrier graphite crucibles
Field of application ceramics, engineering / electronics, steel / metallurgy
Furnace electrode impulse furnace (max. 8,5 KW*), temperatures in excess of 3,000 °C
Detection method solid state infrared absorption for oxygen thermal conductivity for nitrogen
Typical analysis time 120 - 180 s
Chemicals required copper oxide, magnesium perchlorate, sodium hydroxide
Gas required compressed air, helium 99.995 % pure, argon 99.995% pure (if required), all gases with (2 - 4 bar / 30 - 60 psi)
Power requirements 3~ 400 V, 50/60 Hz, max. 8,500 W
Dimensions (W x H x D) 570 x 770 x 630 mm / 22.44 x 30.31 x 24.8 in
Weight ~ 161 kg
Required equipment PC, monitor, balance (resolution 0.0001g)
Optional accessories carrier gas purification, external chiller, gas calibration unit

Full documentation — TDS, SDS, batch COA, and parameter sets for the major LPBF platforms. Everything you need for qualification under AS9100 / ISO 13485 workflows.

Don't see your spec?

We atomize our own. Custom variants on request.

Tighter PSD, modified chemistry, custom blend? Our ATO atomization lab runs custom batches in 3–4 weeks. Biocompatible, refractory, proprietary — all in-house, verified before ship.

Frequently bought together

Complete the workflow

What teams add to an order so the first build runs clean — handling, plates, and a sample to qualify before you commit volume.

ELEMENTRAC CS‑d
Analysis equipment
ELEMENTRAC CS‑d
ELEMENTRAC CS-d is the only analyzer in the market for determination of carbon and sulfur in organic
ELEMENTRAC CS‑r
Analysis equipment
ELEMENTRAC CS‑r
For the safe, precise and reliable elemental analysis of carbon (C) and sulfur (S) in predominantly organic matrices
ELEMENTRAC OH‑p 2
Analysis equipment
ELEMENTRAC OH‑p 2
ELEMENTRAC OH-p 2 is a elemental analyzer for measurement of oxygen and hydrogen concentrations
ELEMENTRAC ONH‑p 2
Analysis equipment
ELEMENTRAC ONH‑p 2
ELEMENTRAC ONH-p 2 is a powerful and robust elemental analyzer for measurement of oxygen
1 / 1

From process engineers running ELEMENTRAC ON‑p 2

Unedited feedback from customers who reorder ELEMENTRAC ON‑p 2.

★★★★★ 4.9 / 5 · 24 reviews
★★★★★

Same lot 4 times in a row. We stopped re-running parameter sweeps after the second order — density was identical to the first build.

MK
Marcus K. Process Engineer · Aerospace OEM
★★★★★

Asked about ferrite content on a Friday. A materials engineer answered Monday morning with actual data, not a sales pitch. That's why we keep ordering.

PS
Priya S. R&D Lead · Medical Devices
★★★★★

COA matches the bottle. PSD and flow are exactly what was on the sheet — we run it on a Renishaw 500Q and it hits density on the first try.

DR
Diego R. Production Lead · Energy

Place your order, or talk to an engineer first

Order ELEMENTRAC ON‑p 2 direct, or talk to materials engineer

Add to cart