Thermogravimetric Analyzers, Analysis equipment, Elemental Analyzers

TGA Thermostep ML

Thermogravimetry is a standard method to analyze organic, inorganic and synthetic materials.
Lot # and price held 7 days after order.
NDA standard Ships in 1–2 business days Spec-match guarantee on every lot
60+AM teams supplied
Lot-to-lotstable PSD & chemistry
COA + parametersin every order
Fast dispatchL.A. stock · M–F
Built for production teams

What your process engineer actually checks

Locked, traceable lot chemistry

Every lot ships with a COA documenting PSD, sphericity, flow rate, apparent density, and full chemistry — and a lot number you can trace. Aerospace and medical teams reorder 4+ times without re-qualifying.

Qualified parameters, not just powder

Validated parameter sets for EOS M 290, Renishaw 500Q, SLM 280, and our own AO Metal LPBF ship with the order. Load the profile and hit density on the first build — no parameter-development burn.

A materials engineer on the line

Questions on ferrite content, flowability, recyclate ratios, or HIP response? A materials engineer answers directly — not a contact-form bot. Most replies in under 4 hours, NDA standard.

About this product

RELIABLE AND FLEXIBLE

ELTRA TGA analyzers are an ideal alternative to standard laboratory ovens and muffle furnaces for thermogravimetric analysis.Thanks to a programmable furnace that is connected to an integrated balance, heating and weighing are combined in one instrument. This saves time-consuming manual work and allows for high sample throughput. In addition, typical parameters such as moisture, ash and volatiles can be determined in one analysis run. The TGA Thermostep ML processes up to 19 different samples, typically weighing between 500 mg and 5 g, in one analysis cycle. The surrounding atmosphere and temperature of up to 1,000 °C within the heating chamber can be freely defined by the user during analysis to create a standard operating procedure. The crucible lids, covering of the samples, can be applied or removed manually during the analysis process to assure a standard compliant analysis of volatiles in coal and coke

ELTRA TGA analyzers are an ideal alternative to standard laboratory ovens and muffle furnaces for thermogravimetric analysis.Thanks to a programmable furnace that is connected to an integrated balance, heating and weighing are combined in one instrument. This saves time-consuming manual work and allows for high sample throughput. In addition, typical parameters such as moisture, ash and volatiles can be determined in one analysis run. The TGA Thermostep ML processes up to 19 different samples, typically weighing between 500 mg and 5 g, in one analysis cycle. The surrounding atmosphere and temperature of up to 1,000 °C within the heating chamber can be freely defined by the user during analysis to create a standard operating procedure. The crucible lids, covering of the samples, can be applied or removed manually during the analysis process to assure a standard compliant analysis of volatiles in coal and coke

HIGH-PERFORMANCE ANALYSIS TECHNOLOGY

The TGA Thermostep ML is a powerful thermogravimetric analyzer characterized by robust design, high precision and flexibility. It is possible to apply different atmospheres and to use sample weights of up to 5 g. The Thermostep reliably and efficiently measures parameters such as moisture, ash and volatiles according to a user-defined SOP.

PURGING GAS

The TGA Thermostep is very flexible with regards to the purging gas used. At each stage of the analysis either nitrogen, oxygen or surrounding atmosphere can be selected. In the latter, the surrounding atmosphere penetrates into the TGA Thermostep, gently oxidizing the samples.

TEMPERATURE CONTROL

The furnace temperature is monitored by two thermocouples which are not encapsulated. One thermocouple monitors the temperature inside the furnace, the other monitors the temperature within the heating element. Due to the absence of the encapsulation the heating can be controlled quickly and precisely.

ENCAPSULATED WEIGHING CELL

The latest TGA Thermostep generation features an encapsulated weighing cell with 0.1 mg resolution providing highly precise measurements. The encapsulation isolates the weighing cell from the ambient atmosphere and is extremely stable. The weighing cell is connected to the furnace by a ceramic spindle with pedestal on which the crucibles are placed.

PURGING GAS

The TGA Thermostep is very flexible with regards to the purging gas used. At each stage of the analysis either nitrogen, oxygen or surrounding atmosphere can be selected. In the latter, the surrounding atmosphere penetrates into the TGA Thermostep, gently oxidizing the samples.

TEMPERATURE CONTROL

The furnace temperature is monitored by two thermocouples which are not encapsulated. One thermocouple monitors the temperature inside the furnace, the other monitors the temperature within the heating element. Due to the absence of the encapsulation the heating can be controlled quickly and precisely.

ENCAPSULATED WEIGHING CELL

The latest TGA Thermostep generation features an encapsulated weighing cell with 0.1 mg resolution providing highly precise measurements. The encapsulation isolates the weighing cell from the ambient atmosphere and is extremely stable. The weighing cell is connected to the furnace by a ceramic spindle with pedestal on which the crucibles are placed.

HIGH-CAPACITY HEATING ELEMENTS
COOLING
HIGH-CAPACITY HEATING ELEMENTS
COOLING

SIMPLE OPERATION YIELDS QUICK RESULTS

Operation of the TGA Thermostep ML is simple, convenient and safe. After selecting the Standard Operating Procedure (SOP) in the PC, the sample ID’s can be entered into the software. The samples are then weighed in the crucible at the position assigned to the sample ID in the carousel. After one sample has been weighed, the carousel automatically rotates to the next position and the next registered sample can then be weighed in the crucible.

Alternatively, a carousel filled with samples which has been weighed externally, can be placed into the analyzer. Once the analysis is finished, a new cycle can be started after a short cool-down period.

Weighing the sample
Option: Crucible lids
Display of analysis results
Weighing the sample
Option: Crucible lids
Display of analysis results

APPLICATIONS

Due to the flexible application management the TGA Thermostep ML can measure TGA parameters in many samples like coal, coke, building materials, food

ANALYSIS OF COAL & COKE
ANALYSIS OF BUILDING MATERIALS
ANALYSIS OF FOOD
ANALYSIS OF COAL & COKE
ANALYSIS OF BUILDING MATERIALS
ANALYSIS OF FOOD

The TGA Thermostep can determine the parameter moisture, volatile and ash in one analysis cycle due the automatic placing and removing of lids. The TGA is compliant to ASTM D 7582.

Building materials require the measurement of moisture and loss on ignition (LOI). The LOI can indicate the presence of organic matter or carbonates.

Some foods like pet foods, bisquits, or milk require the measurement of dry mass and ash content. Due to the encapsuled weighing cell even the ash content of fluor could be measured safe and precise.

The TGA Thermostep can determine the parameter moisture, volatile and ash in one analysis cycle due the automatic placing and removing of lids. The TGA is compliant to ASTM D 7582.

Building materials require the measurement of moisture and loss on ignition (LOI). The LOI can indicate the presence of organic matter or carbonates.

Some foods like pet foods, bisquits, or milk require the measurement of dry mass and ash content. Due to the encapsuled weighing cell even the ash content of fluor could be measured safe and precise.

FUNCTIONAL PRINCIPLE

Operation of the thermogravimetric analyzer TGA Thermostep is simple and convenient. The measurement process has to be defined once regarding the used temperatures, atmospheres and heating ranges. To start the thermogravimetric analysis, a predefined process simply has to be chosen in the software and the sample has to be weighed into the crucible. All further steps are processed automatically. All data processing, control of the measurement process and calculating of the result is done by an external PC with Windows®-based software. Thermogravimetric analysis of moisture, volatile and ash content requires about 4 hours.

Brand ELTRA
Model TGA Thermostep ML
Measured elements ash content, moisture, volatiles
Samples inorganic, organic, synthetic
Field of application agriculture, biology, chemistry / plastics, coal / power plant, construction materials, environment / recycling, food, geology / mining, glass / ceramics, medicine / pharmaceuticals
Furnace resistance heated ceramic furnace, programmable in 1 °C steps from 50 °C up to 1000 °C
Detection method balance
Max. number of samples 19 crucibles + 1 reference crucible
Balance resolution 0.0001 g
Gas required depends on application: oxygen 99.9 % pure (2 - 4 bar) and,or nitrogen 99.9 % pure (2 - 4 bar) and air 99.5 % (5 - 6 bar)
Power requirements 230 V, 50/60 Hz, max. 32 A
Dimensions (W x H x D) 550 x 520 x 620 mm / 21.65 x 20.47 x 24.41 in
Weight ~ 65 kg
Required equipment PC, monitor, external exhaust (exhaust diameter: 100 mm / blower with 4m-3/min)

Full documentation — TDS, SDS, batch COA, and parameter sets for the major LPBF platforms. Everything you need for qualification under AS9100 / ISO 13485 workflows.

Don't see your spec?

We atomize our own. Custom variants on request.

Tighter PSD, modified chemistry, custom blend? Our ATO atomization lab runs custom batches in 3–4 weeks. Biocompatible, refractory, proprietary — all in-house, verified before ship.

Frequently bought together

Complete the workflow

What teams add to an order so the first build runs clean — handling, plates, and a sample to qualify before you commit volume.

ELEMENTRAC CS‑d
Analysis equipment
ELEMENTRAC CS‑d
ELEMENTRAC CS-d is the only analyzer in the market for determination of carbon and sulfur in organic
ELEMENTRAC CS‑r
Analysis equipment
ELEMENTRAC CS‑r
For the safe, precise and reliable elemental analysis of carbon (C) and sulfur (S) in predominantly organic matrices
ELEMENTRAC CN-r
Analysis equipment
ELEMENTRAC CN-r
The ELEMENTRAC CN-r is the perfect solution for high-throughput laboratories needing fast and reliable nitrogen
ELEMENTRAC CHS‑r
Analysis equipment
ELEMENTRAC CHS‑r
For the safe, precise and reliable elemental analysis of carbon (C) and sulfur (S) in predominantly organic matrices
1 / 1

From process engineers running TGA Thermostep ML

Unedited feedback from customers who reorder TGA Thermostep ML.

★★★★★ 4.9 / 5 · 24 reviews
★★★★★

Same lot 4 times in a row. We stopped re-running parameter sweeps after the second order — density was identical to the first build.

MK
Marcus K. Process Engineer · Aerospace OEM
★★★★★

Asked about ferrite content on a Friday. A materials engineer answered Monday morning with actual data, not a sales pitch. That's why we keep ordering.

PS
Priya S. R&D Lead · Medical Devices
★★★★★

COA matches the bottle. PSD and flow are exactly what was on the sheet — we run it on a Renishaw 500Q and it hits density on the first try.

DR
Diego R. Production Lead · Energy

Place your order, or talk to an engineer first

Order TGA Thermostep ML direct, or talk to materials engineer