Made to order
- Installation & training gas & exhaust connection and operator onboarding
- Method + validation an SOP validated against your standard
ELTRA TGA Thermostep ML Thermogravimetric Analyzer – Manual-Lid Moisture, Ash & Volatiles | 19 Samples
Manual-lid thermogravimetric analyzer — programmable furnace plus integrated balance measures moisture, ash and volatiles in up to 19 samples per run, 50–1,000 °C. A more economical route to standard-compliant TGA.
- ✔ 19 samples + 1 reference · 500 mg–5 g · moisture/ash/volatiles in one run
- ✔ Ceramic furnace 50–1,000 °C · N₂/O₂/air per stage · manual crucible lids
- ✔ Encapsulated balance 0.1 mg · ASTM D 7582 compliant
- ✔ Lead time: configured to order — request current timeline
What your QC lab actually checks
Automated TGA, manual crucible lids
The TGA Thermostep ML runs the same automated moisture/ash/volatiles cycle on up to 19 samples plus a reference, 50–1,000 °C, with an encapsulated 0.1 mg balance. Crucible lids are handled manually rather than automatically — a lower-cost route to ASTM D 7582-compliant coal and coke analysis and LOI on many materials.
An applications engineer on the line
SOP setup, standard validation and throughput-workflow development from engineers who run materials characterization in-house. Sub-4h reply, NDA standard.
The ELTRA TGA Thermostep ML is the manual-lid version of the Thermostep thermogravimetric analyzer. It combines a programmable furnace with an integrated balance to measure moisture, ash and volatiles in one automated run, on up to 19 samples plus a reference, at 50–1,000 °C. Crucible lids are placed and removed by hand during the analysis — a more economical route to standard-compliant coal and coke analysis with the same precise weighing.
Why QC labs choose the TGA Thermostep ML
The same automated thermogravimetry, with manual crucible lids for a lower-cost route.
19 samples in one run
A carousel takes up to 19 crucibles plus a reference (500 mg–5 g each). Weigh in place or load a pre-weighed carousel — high throughput without manual oven-and-balance cycling.
Moisture, ash & volatiles together
A programmable ceramic furnace (50–1,000 °C in 1 °C steps) determines all three in one cycle. Crucible lids are applied and removed manually for ASTM D 7582-compliant coal and coke volatiles.
Selectable atmospheres
Choose nitrogen, oxygen or ambient air at each stage of the analysis to oxidize or protect the sample exactly when the method requires it.
Precise, reference-corrected weighing
An encapsulated weighing cell (0.1 mg resolution) with a dedicated reference crucible that compensates crucible weight loss at high temperature — stable, accurate results.
How Additive Plus supports it
A configured, installed analyzer with your TGA methods ready to run.
Configure to your samples
We set up the SOPs — temperatures, atmospheres and heating stages — for your material and standard before it ships.
Install & train
Factory-trained engineers install, connect the gases and exhaust, and train your team on weighing, lid handling and results.
Method & QC support
We help validate the method against your standard — ASTM D 7582, LOI or dry-mass/ash — for a repeatable workflow.
What the TGA Thermostep ML measures
Full technical specifications are in the Specifications tab. Key measurement capability:
| Parameter | TGA Thermostep ML |
|---|---|
| Measures | Moisture, ash, volatiles (loss on ignition) |
| Samples per run | 19 crucibles + 1 reference · 500 mg – 5 g each |
| Furnace | Resistance-heated ceramic, 50–1,000 °C in 1 °C steps |
| Crucible lids | Placed and removed manually during analysis |
| Balance | Encapsulated cell, 0.1 mg resolution |
| Standards | ASTM D 7582 (coal / coke volatiles) · LOI methods |

Typical applications
Moisture, ash and volatiles across many industries.
Not sure the TGA Thermostep ML is the right fit?
Automatic crucible lids, or a different elemental measurement.
Surface carbonELTRA SurfaceC-800Compare analyzer →
Fit out the labQATM Lab FurnitureView system →
Why source the TGA Thermostep ML through Additive Plus
- Authorized channel for ELTRA / Verder Scientific lab equipment — sales, installation, training and service in one place.
- Full materials-QC line — thermogravimetry, carbon analysis, sample prep and optical inspection from one partner.
- Method development on your samples — SOPs, standard validation and a repeatable throughput workflow.
- <24h response from engineers who run materials characterization in-house. NDA standard.
| Brand | ELTRA |
| Model | TGA Thermostep ML |
| Measured elements | ash content, moisture, volatiles |
| Samples | inorganic, organic, synthetic |
| Field of application | agriculture, biology, chemistry / plastics, coal / power plant, construction materials, environment / recycling, food, geology / mining, glass / ceramics, medicine / pharmaceuticals |
| Furnace | resistance heated ceramic furnace, programmable in 1 °C steps from 50 °C up to 1000 °C |
| Detection method | balance |
| Max. number of samples | 19 crucibles + 1 reference crucible |
| Balance resolution | 0.0001 g |
| Gas required | depends on application: oxygen 99.9 % pure (2 - 4 bar) and,or nitrogen 99.9 % pure (2 - 4 bar) and air 99.5 % (5 - 6 bar) |
| Power requirements | 230 V, 50/60 Hz, max. 32 A |
| Dimensions (W x H x D) | 550 x 520 x 620 mm / 21.65 x 20.47 x 24.41 in |
| Weight | ~ 65 kg |
| Required equipment | PC, monitor, external exhaust (exhaust diameter: 100 mm / blower with 4m-3/min) |
Common questions
Don't see yours? Email [email protected] — NDA standard, typical reply within 4 hours.
How is the TGA Thermostep ML different from the TGA Thermostep?
What does the TGA Thermostep ML measure?
How many samples can it run at once?
Is it compliant for coal and coke analysis?
Which materials and standards is it used for?
What does it need to run?
What is the lead time, and can Additive Plus set it up?
Place your order, or talk to an engineer first
Order ELTRA TGA Thermostep ML Thermogravimetric Analyzer – Manual-Lid Moisture, Ash & Volatiles | 19 Samples direct, or talk to materials engineer