ELTRA ELEMENTRAC OH-p 2 Oxygen/Hydrogen Analyzer – Inert Gas Fusion | Steel, Metals & Ceramics
Inert-gas-fusion analyzer for oxygen and total hydrogen in metals — the sample melts in a graphite crucible in an 8.5 kW impulse furnace above 3,000 °C, with IR detection of oxygen and thermal conductivity for hydrogen.
- ✔ O / H by fusion · single or combined OH · inorganic samples
- ✔ 8.5 kW impulse furnace > 3,000 °C · closed gas system · low detection limits
- ✔ Up to 2000 mg · nitrogen carrier · Schuetze reagent · Autocleaner option
- ✔ Lead time: configured to order — request current timeline
What your QC lab actually checks
Oxygen and hydrogen in metals by fusion
An 8.5 kW electrode impulse furnace melts the sample in a graphite crucible above 3,000 °C; oxygen is measured as CO₂ by infrared and total hydrogen by a high-sensitivity thermal conductivity cell with a nitrogen carrier. A closed gas system feeds 100 % of the sample gas to the detectors for low detection limits — the oxygen and total-hydrogen numbers that matter in steel, titanium and metal AM parts. Single-element or combined OH, robust and low-maintenance.
An applications engineer on the line
Mode and carrier-gas selection, gas calibration, crucible outgassing and blank control from engineers who run metal additive manufacturing in-house (AO Metal). Sub-4h reply, NDA standard.
The ELTRA ELEMENTRAC OH-p 2 determines oxygen and hydrogen in metals and inorganic materials by inert gas fusion. The sample melts in a graphite crucible in a powerful 8.5 kW electrode impulse furnace above 3,000 °C; oxygen is measured as CO₂ in up to two infrared cells, while hydrogen is detected in its elemental form in a high-sensitivity thermal conductivity cell using a nitrogen carrier. A closed gas system feeds 100 % of the released sample gas to the detectors for low detection limits on steel, titanium and metal AM parts.
Why metallurgy and AM labs choose the OH-p 2
Oxygen and hydrogen in metals — total-hydrogen fusion, low detection limits.
O + H by inert gas fusion
An 8.5 kW electrode impulse furnace melts the sample in a graphite crucible above 3,000 °C — oxygen is measured as CO₂ by IR and total hydrogen by thermal conductivity. Single-element or combined OH.
Closed gas system, low limits
A closed gas system under overpressure feeds 100 % of the released sample gas to the detectors, guaranteeing low detection limits and good reproducibility on demanding metals.
Sample port up to 2000 mg
Solid pieces, granules or powder in capsules load up to 2,000 mg and are freed of atmosphere by pulsed carrier-gas flushing before dropping into the crucible — robust against dust, no capsule closing needed.
Schuetze reagent + Autocleaner
A Schuetze reagent converts CO to CO₂ for oxygen while hydrogen stays elemental for the TC cell; the optional Autocleaner removes furnace deposits for precise, high-throughput analysis.
How Additive Plus supports it
A configured, installed analyzer with an O/H method dialed in on your metals.
Configure to your samples
We spec the O, H or OH mode, carrier gas and Autocleaner to your alloy or powder and detection range before it ships.
Install & train
Factory-trained engineers install the analyzer, connect the three-phase power, gases and PC/balance, and train your team on the ELEMENTS software.
Method & QC support
We help build the SOP — gas calibration, crucible outgassing, blank control and a repeatable oxygen/hydrogen baseline.
What the OH-p 2 measures
Full technical specifications are in the Specifications tab. Key measurement capability:
| Parameter | ELEMENTRAC OH-p 2 |
|---|---|
| Measured elements | Oxygen, hydrogen (single or combined OH) |
| Principle | Inert gas fusion — electrode impulse furnace > 3,000 °C (8.5 kW) |
| Detection | IR for oxygen (as CO₂) · thermal conductivity for hydrogen |
| Sample weight | Up to 2,000 mg · pins, granules or powder in capsules |
| Analysis time | ~120–180 seconds |
| Carrier gas | Nitrogen 99.995 % |


Typical sample materials
Oxygen and total hydrogen in metals and inorganic materials.
Not sure the OH-p 2 is the right analyzer?
Compare with related ELEMENTRAC and hydrogen analyzers in our catalog.
Oxygen + nitrogenELEMENTRAC ON-p 2View analyzer →
Diffusible hydrogenELTRA H-500View analyzer →
Why source the OH-p 2 through Additive Plus
- Authorized channel for ELTRA / Verder Scientific lab equipment — sales, installation, training and service in one place.
- Configured to your samples — O/H/OH mode, carrier gas and Autocleaner specified before shipping.
- Method development on your metals — gas calibration, crucible outgassing and a repeatable O/H SOP; relevant to metal AM powder QC.
- <24h response from engineers who run metal additive manufacturing in-house (AO Metal). NDA standard.
| Brand | ELTRA |
| Model | ELEMENTRAC OH-p 2 |
| Measured elements | hydrogen, oxygen |
| Samples | inorganic |
| Furnace alignment | vertical |
| Sample carrier | graphite crucibles |
| Field of application | ceramics, engineering / electronics, steel / metallurgy |
| Furnace | electrode impulse furnace (max. 8,5 KW*), temperatures in excess of 3,000 °C |
| Detection method | solid state infrared absorption for oxygen, thermal conductivity for hydrogen |
| Typical analysis time | 120 - 180 s |
| Chemicals required | Schuetze reagents, magnesium perchlorate, sodium hydroxide |
| Gas required | compressed air, nitrogen 99.995 % pure, all gases with (2 - 4 bar / 30 - 60 psi) |
| Power requirements | 3~ 400 V, 50/60 Hz, max. 8,500 W |
| Dimensions (W x H x D) | 560 x 780 x 640 mm / 22.05 x 30.71 x 25.2 in |
| Weight | ~ 165 kg |
| Required equipment | PC, monitor, balance (resolution 0.0001g) |
| Optional accessories | carrier gas purification, external chiller, gas calibration unit |
Product videos
From metallurgy and AM labs running the ELTRA ELEMENTRAC OH-p 2
Unedited feedback from materials-QC teams.
Oxygen and total hydrogen on steel with low detection limits. The closed gas system keeps our results tight lot to lot.
Total hydrogen and oxygen on titanium AM parts is exactly what our qualification needs. Up to 2000 mg means representative samples.
The sample port takes granules without closing capsules, and the Autocleaner keeps long runs reproducible.
Common questions
Don't see yours? Email [email protected] — NDA standard, typical reply within 4 hours.
What does the ELTRA ELEMENTRAC OH-p 2 measure?
How does the inert gas fusion measurement work?
How is the OH-p 2 different from the H-500?
Is the OH-p 2 suitable for titanium and metal AM QC?
What sample sizes and automation does it offer?
What does the OH-p 2 need to run?
What is the lead time, and can Additive Plus set it up?
Place your order, or talk to an engineer first
Order ELTRA ELEMENTRAC OH-p 2 Oxygen/Hydrogen Analyzer – Inert Gas Fusion | Steel, Metals & Ceramics direct, or talk to materials engineer