ELTRA ELEMENTRAC CHS-r Carbon/Hydrogen/Sulfur Analyzer – Resistance Furnace + IR | 20 ppm–100%
Resistance-furnace analyzer for fast, simultaneous carbon, hydrogen and sulfur in organic matrices — combustion up to 1,550 °C with a heated H₂O infrared cell for hydrogen and solid-gold IR cells over 20 ppm to 100 %.
- ✔ Simultaneous C / H / S · 20 ppm–100 % · high sample weights
- ✔ Resistance furnace to 1,550 °C · heated H₂O IR cell · up to 3 solid-gold IR cells
- ✔ Low-blank sample port · dual-furnace option · TIC module (DIN EN 15936)
- ✔ Lead time: configured to order — request current timeline
What your QC lab actually checks
Carbon, hydrogen and sulfur in one run
Combustion in a resistance furnace to 1,550 °C, with a heated H₂O infrared cell followed by additional gold infrared cells, determines carbon, hydrogen and sulfur simultaneously from 20 ppm to 100 %. An optimized low-blank sample port with reduced diameter and oxygen purge drastically lowers the atmospheric CO₂ blank, so even low-carbon organic samples are measured reliably. An optional second furnace adds fast fractionated analysis.
An applications engineer on the line
IR-cell and hydrogen-cell configuration, low-blank port setup, calibration and blank control from engineers who run materials characterization in-house. Sub-4h reply, NDA standard.
The ELTRA ELEMENTRAC CHS-r is a resistance-furnace analyzer for fast, simultaneous carbon, hydrogen and sulfur in predominantly organic matrices. The sample is burned in oxygen at up to 1,550 °C; the combustion gases first pass a heated H₂O infrared cell for hydrogen, then the CO₂ and SO₂ are measured in additional infrared cells over a wide range from 20 ppm to 100 %. An optimized low-blank sample port and solid-gold IR paths give reliable low-carbon analysis and extended cell life.
Why materials and environmental labs choose the CHS-r
Carbon, hydrogen and sulfur in one run — down to low ppm, up to 100 %.
Simultaneous C/H/S
Fast, simultaneous carbon, hydrogen and sulfur in a resistance furnace up to 1,550 °C, with high sample weights for heterogeneous organic matrices.
Heated H₂O IR cell for hydrogen
A dedicated heated water infrared cell captures the hydrogen as H₂O directly after the furnace, adding hydrogen to the carbon and sulfur determination.
Low-blank port, 20 ppm–100 %
A reduced-diameter sample port with oxygen purge drastically lowers the atmospheric CO₂ blank, enabling reliable carbon analysis in the low measuring range down to 20 ppm.
Gold IR path, dual-furnace + TIC
Solid-gold IR paths extend cell life, two drying columns protect the optics, and options include a second furnace for fractionated analysis and a TIC module.
How Additive Plus supports it
A configured, installed analyzer with a C/H/S method dialed in on your samples.
Configure to your samples
We spec the IR cells, hydrogen cell, sample-port, dual-furnace and TIC options to your matrix and concentration range before it ships.
Install & train
Factory-trained engineers install the analyzer, connect oxygen and the PC/balance, and train your team on the ELEMENTS software.
Method & QC support
We help build the SOP — calibration with standards, blank control, TOC method and a repeatable C/H/S baseline.
What the CHS-r measures
Full technical specifications are in the Specifications tab. Key measurement capability:
| Parameter | ELEMENTRAC CHS-r |
|---|---|
| Measured elements | Carbon, hydrogen, sulfur (organic samples) |
| Measuring range | 20 ppm to 100 % |
| Principle | Resistance furnace to 1,550 °C (1 °C steps) + heated H₂O IR cell + solid-state IR |
| Detection | 1–3 infrared cells · solid-gold IR path |
| Analysis time | ~60–180 seconds |
| Requirements | Oxygen 99.5 % · PC, monitor, 0.0001 g balance |


Typical sample materials
Carbon, hydrogen and sulfur in fuels, biomass, soils and organic matrices.
Not sure the CHS-r is the right analyzer?
Compare with other ELEMENTRAC combustion analyzers.
A-series C/H/SELTRA CHS-580AView analyzer →
Dual furnaceELEMENTRAC CS-dView analyzer →
Why source the CHS-r through Additive Plus
- Authorized channel for ELTRA / Verder Scientific lab equipment — sales, installation, training and service in one place.
- Configured to your samples — IR cells, hydrogen cell, sample-port and TIC options specified before shipping.
- Method development on your samples — calibration, blank control and a repeatable C/H/S / TOC SOP.
- <24h response from engineers who run materials characterization in-house. NDA standard.
| Brand | ELTRA |
| Model | ELEMENTRAC CHS‑r |
| Measured elements | carbon, hydrogen, sulfur |
| Samples | organic |
| Furnace alignment | horizontal (resistance furnace) |
| Sample carrier | ceramic boats |
| Field of application | agriculture, biology, chemistry / plastics, coal / power plant, construction materials, environment / recycling, medicine / pharmaceuticals |
| Furnace | resistance furnace (ceramic tube), adjustable up to 1550 °C (steps of 1 °C) |
| Detection method | solid state infrared absorption |
| Number of IR cells | 1 - 3 |
| Material of IR path | gold |
| Typical analysis time | 60 - 180 s |
| Chemicals required | magnesium perchlorate, sodium hydroxide |
| Gas required | oxygen 99.5 % pure (2 - 4 bar / 30 - 60 psi) |
| Power requirements | 230 V, 50/60 Hz max. heat up current 2000 W |
| Dimensions (W x H x D) | 580 x 520 x 750 mm / 22.83 x 20.47 x 29.53 in |
| Weight | ~ 77 kg |
| Required equipment | PC, monitor, balance (resolution 0.0001g) |
| Optional accessories | TIC module |
Product videos
From materials and environmental labs running the ELTRA ELEMENTRAC CHS-r
Unedited feedback from combustion-analysis teams.
Carbon, hydrogen and sulfur on coal in a single run. The heated water cell added hydrogen without slowing us down.
C/H/S on plastics and rubber compounds is repeatable, and the low-blank port helps with our trace-carbon work.
Hydrogen and carbon on biomass fuels for our reporting. Calibration with standards is quick and stable.
Common questions
Don't see yours? Email [email protected] — NDA standard, typical reply within 4 hours.
What does the ELTRA ELEMENTRAC CHS-r measure?
How is hydrogen measured?
How does the low-blank sample port help?
Can the CHS-r run TOC and TIC?
What is the dual-furnace option?
What does the CHS-r need to run?
What is the lead time, and can Additive Plus set it up?