Equipment
Direct Pellet Extrusion (DPE) head for the 3DCeram M.A.T. — print ceramic & metal pellets at lower feedstock cost than filament.
- ✓ Screw Ø8 mm · 270 °C max · 0.8 mm nozzle
- ✓ Lower cost per part vs. filament, higher throughput
- ✓ Installs on your M.A.T. — US support & training
Add-on for the 3DCeram M.A.T. · requires the base system · made to order
In stock
Acid sites, reducibility, coke and metal dispersion of a solid catalyst on one automatic instrument — TPD, TPR, TPO and pulse chemisorption from −120 to 1200 °C.
- Eight gas ports, mixtures blended inside the instrument
- Breakthrough curves and BET; BELMASS II option to identify the gases
- Installation and on-site training included · free test analysis of your catalyst
- Configured to order · lead time from 4 weeks
Made to order
· Lead time from 4 weeks · installation included
Cryogenic unit for BELSORP analyzers — adsorption isotherms at any temperature from 35 to 473 K without liquid nitrogen, stability to ±0.001 K.
- Add-on for BELSORP MAX X (incl. HP), MAX G and MINI X
- Up to 3 samples, fully automated in BELControl
- Installation and on-site training included · free test analysis of your sample
- Configured to order · lead time from 4 weeks
Made to order
· Lead time from 4 weeks · installation included
An add-on mass spectrometer for the BELCAT II that tells you which gases evolve in TPD, TPR and breakthrough runs — m/z 1 to 200, up to 16 mass numbers followed at once.
- Faraday cup or SEM detector, resolution M/ΔM ≥ 2M
- Heated hose up to 200 °C for vapors, including ammonia
- Installation and on-site training included · free test analysis of your sample
- Configured to order · lead time from 4 weeks
Made to order
· Lead time from 4 weeks · installation included
Pore size distribution and pore volume by mercury intrusion — 3.6 nm to 180 µm, to 1 mm with the Ultra-Macropore Set, up to 414 MPa and 20,000 measuring points.
- LP plus MP or HP · PoreInspect runs up to four from one PC
- No gas connection or liquid nitrogen · moist samples on the LP
- Installation and on-site training included · free test analysis of your sample
- Configured to order · lead time from 4 weeks
Made to order
· Lead time from 4 weeks · installation included
Vacuum degasser for BELSORP gas adsorption analyzers — prepares 3 or 6 samples at up to 430 or 450 °C while the analyzer measures.
- Vacuum / heat degassing, flow / heat under inert gas as an option
- Add-on for BELSORP MINI X, MAX G and MAX X analyzers
- Installation and on-site training included · free test analysis of your sample
- Configured to order · lead time from 4 weeks
Made to order
· Lead time from 4 weeks · installation included
True (skeletal) density of powders and porous solids by gas displacement — helium or nitrogen, 10, 3.5 and 1 cm³ sample cells.
- Accuracy 0.03% of full scale + 0.03% of reading · repeatability 0.02%
- Benchtop, 8 kg · the reference value for porosity calculations
- Installation and on-site training included · free test analysis of your sample
- Configured to order · lead time from 4 weeks
Made to order
· Lead time from 4 weeks · installation included
Micropore-capable BET surface area and pore size analyzer — isotherms from P/P₀ = 10⁻⁸, pores 0.35 to 500 nm, krypton down to 0.0005 m²/g.
- One measurement port with dedicated p₀ and free-space ports, AFSM™ accuracy
- BET, BJH, HK, SF and NLDFT / GCMC analysis in BELMASTER 7
- Installation and on-site training included · free test analysis of your sample
- Configured to order · lead time from 4 weeks
Made to order
· Lead time from 4 weeks · installation includedNot sure which system fits?
Tell us your application. We'll send our top recommendation.
Browse all categories
Printers, materials, print services and lab equipment — including AO Metal, the LPBF printer we design and build ourselves.
Have a CAD? Have a quote in 24h.
Upload your file or talk to an engineer — no obligation, no spam, NDA on request. First-time customers get free DfAM review.