Made to order
- Installation & training setup and BELCONTROL/BELMASTER 7 onboarding
- Validated first run a micropore or BET measurement on your sample
Microtrac BELSORP MAX G Gas Adsorption Analyzer – BET Surface Area & Micropore | 0.35–500 nm
Dedicated volumetric gas adsorption analyzer for BET surface area and micro-to-mesopore distribution — ultra-low pressure to P/P₀ 10⁻⁸, from 0.0005 m²/g with krypton.
- ✔ Surface area from 0.01 m²/g (N₂), 0.0005 m²/g (Kr)
- ✔ Pore size 0.35–500 nm · micropore via HK/SF/NLDFT
- ✔ Ultra-low pressure P/P₀ = 10⁻⁸ · up to 5 ports
- ✔ Lead time: configured to order — request current timeline
What your process engineer actually checks
Micropores without the floor space
Ultra-low-pressure adsorption to P/P₀ 10⁻⁸ resolves micropores in a compact 36 kg gas analyzer — MAX-class resolution for gas-only work, on a bench rather than the floor.
A materials engineer on the line
Configuration and BET, t-plot, NLDFT and GCMC method support from engineers who run surface-area and porosity analysis in-house at Additive Plus. Sub-4h reply, NDA standard.
BELSORP MAX G is a dedicated volumetric gas adsorption analyzer for BET surface area and micro-to-mesopore distribution — ultra-low pressure to P/P₀ 10⁻⁸, from 0.0005 m²/g with krypton, in a compact bench-top frame.
What Is the BELSORP MAX G: Micropore-Capable Gas Adsorption
The BELSORP MAX G measures nitrogen, argon, krypton, CO₂ and other gas isotherms by the volumetric method with AFSM™ free-space technology, then derives BET surface area and micro-to-mesopore distribution. It brings ultra-low-pressure micropore resolution into a compact, gas-only instrument. See full specifications below.



Why labs choose the BELSORP MAX G
Micropore resolution and krypton low-area capability, without a floor-standing analyzer.
Micropore resolution
Ultra-low pressure to P/P₀ 10⁻⁸ with HK, SF, NLDFT and GCMC models resolves micropores in zeolites, MOFs and carbons.
Krypton low-area
Surface area from 0.0005 m²/g with krypton — the dense, low-surface-area samples that nitrogen adsorption struggles to resolve.
Compact & expandable
Two standard ports expand to five; 36 kg bench-top. Micropore capability without committing to a full-size floor instrument.
Helium-free option
AFSM™ free-space measurement is available — fewer consumables and no constant liquid-nitrogen level top-ups during long runs.
How Additive Plus delivers it
Configured to your materials, installed and method-supported.
Configure
We set port count, gases (including krypton for low-area work) and the cryostat option to your materials.
Install & train
Installation, BELCONTROL and BELMASTER 7 training and a validated first micropore or BET run on your own sample.
Method support
BET, t-plot, NLDFT and GCMC method support from engineers who run surface-area and porosity analysis in-house.
Specifications at a Glance
Key figures below — the full set is in the Specifications tab.
| Parameter | Specification |
|---|---|
| Method | Volumetric + AFSM™ (gas only) |
| Surface area | From 0.01 m²/g (N₂); 0.0005 m²/g (Kr) |
| Pore size | 0.35–500 nm |
| Min. relative pressure | P/P₀ = 10⁻⁸ |
| Ports | 2 standard, up to 5 |
| Gases | N₂, Ar, Kr, CO₂, H₂, O₂, CH₄, CO, NO, butane |
Typical applications
Where micropore structure and low-area surfaces decide performance.
Why Source the BELSORP MAX G Through Additive Plus
- Application-matched configuration — ports, gases (including krypton) and cryostat specified to your materials.
- Installation, BELCONTROL/BELMASTER 7 training and a validated first micropore or BET run on your own sample.
- BET, t-plot, NLDFT and GCMC method support from a team that runs surface-area analysis in-house.
- Leasing and financing available for capital lab equipment · <24h response · systems delivered across 23 countries.
| Brand | Microtrac |
| Technology | Gas adsorption (volumetric, BET / micropore) |
| Certification | CE |
| Weight | 79 lb / 36 kg |
Product videos
Send a representative sample and we'll run a micropore or BET measurement on the BELSORP MAX G in our lab, then walk you through the isotherm.
Common questions
Don't see yours? Email [email protected] — NDA standard, typical reply within 4 hours.
How does the BELSORP MAX G differ from the MINI X and MAX X?
What surface area and pore size range does it measure?
When do I need krypton instead of nitrogen?
How many samples can it run and how is it expandable?
Is helium-free measurement available?
What sample pretreatment does it need?
What lead time and support come with the BELSORP MAX G?
Place your order, or talk to an engineer first
Order Microtrac BELSORP MAX G Gas Adsorption Analyzer – BET Surface Area & Micropore | 0.35–500 nm direct, or talk to materials engineer