Made to order
- Installation & training setup and BELCONTROL/BELMASTER 7 onboarding
- Validated first run a BET measurement on your own material
Microtrac BELSORP MINI X Surface Area & Pore Analyzer – Compact BET | 4 Ports, 0.7–500 nm
Compact volumetric gas adsorption analyzer for BET surface area and mesopore distribution — up to four samples in parallel, helium-free, from 0.01 m²/g.
- ✔ Surface area from 0.01 m²/g (N₂) — no krypton needed
- ✔ Pore size 0.7–500 nm (0.35 nm with molecular-probe option)
- ✔ Up to 4 ports, independent 133 kPa transducer per port
- ✔ Lead time: configured to order — request current timeline
What your process engineer actually checks
Routine BET, done fast
Four samples in parallel, helium-free, from 0.01 m²/g — the MINI X turns daily BET and mesopore QC into a walk-up routine, with an independent transducer per port so results don't wait on each other.
A materials engineer on the line
Configuration and BET/BJH/NLDFT method support from engineers who run surface-area analysis in-house at Additive Plus. Sub-4h reply, NDA standard.
BELSORP MINI X is a compact volumetric gas adsorption analyzer for BET surface area and mesopore distribution — up to four samples measured in parallel, helium-free, from 0.01 m²/g.
What Is the BELSORP MINI X: Compact Multi-Port BET
The BELSORP MINI X measures nitrogen (or argon) adsorption isotherms by the volumetric method with AFSM™2 free-space technology, then derives BET surface area and BJH/NLDFT pore distribution. Each of its up to four ports has an independent pressure transducer, so samples run without waiting on one another. See full specifications below.



Why labs choose the BELSORP MINI X
Daily BET and mesopore analysis, faster and on a smaller bench.
Compact BET workhorse
The smallest, lightest multi-port adsorption analyzer — routine BET and mesopore work on a crowded bench, 280×650×465 mm, 38 kg.
Four ports, per-port transducers
Up to four ports, each with its own 133 kPa pressure transducer, measure independently — one slow sample doesn’t hold up the other three.
Helium-free
AFSM™2 free-space measurement removes the helium calibration step and constant liquid-nitrogen top-ups — faster runs, lower running cost.
Low area without krypton
Measures from 0.01 m²/g in nitrogen, so many low-surface-area samples that usually need krypton run directly on the MINI X.
How Additive Plus delivers it
Configured to your samples, installed and method-supported.
Configure
We set port count, gases and the molecular-probe or 21 CFR Part 11 options to your samples and lab requirements.
Install & train
Installation, BELCONTROL and BELMASTER 7 training and a validated first BET run on your own material.
Method support
BET, BJH and NLDFT method support from engineers who run surface-area and porosity analysis in-house.
Specifications at a Glance
Key figures below — the full set is in the Specifications tab.
| Parameter | Specification |
|---|---|
| Method | Volumetric + AFSM™2 (helium-free) |
| Surface area | From 0.01 m²/g (N₂) |
| Pore size | 0.7–500 nm (0.35 nm with molecular probe) |
| Min. relative pressure | P/P₀ = 10⁻⁴ |
| Ports | Up to 4 (3 in high-accuracy mode) |
| Gases | N₂, Ar, CO₂, CH₄, C₂H₆, H₂, butanes |
Typical applications
Where routine BET and mesopore data drive QC and R&D.
Why Source the BELSORP MINI X Through Additive Plus
- Application-matched configuration — ports, gases and molecular-probe or 21 CFR Part 11 options specified to your samples.
- Installation, BELCONTROL/BELMASTER 7 training and a validated first BET run on your own material.
- BET, BJH and NLDFT method support from a team that runs surface-area analysis in-house.
- Leasing and financing available for capital lab equipment · <24h response · systems delivered across 23 countries.
| Brand | Microtrac |
| Technology | Gas adsorption (volumetric, BET / mesopore) |
| Certification | CE |
| Weight | 84 lb / 38 kg |
Product videos
Send a representative sample and we'll run a BET surface area and pore-size measurement on the BELSORP MINI X in our lab, then walk you through the isotherm.
Common questions
Don't see yours? Email [email protected] — NDA standard, typical reply within 4 hours.
How does the BELSORP MINI X differ from the BELSORP MAX X?
What surface area and pore size range does it cover?
What does helium-free measurement change in practice?
How does the four-port design speed up analysis?
Which gases and analysis methods are supported?
How compact is it and what does it need to run?
What lead time and support come with the BELSORP MINI X?
Place your order, or talk to an engineer first
Order Microtrac BELSORP MINI X Surface Area & Pore Analyzer – Compact BET | 4 Ports, 0.7–500 nm direct, or talk to materials engineer